Parent Layer:
Geofísica
Name: Sondeo Eléctrico Vertical
Display Field: ID_SEV
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Copyright Text:
Default Visibility: false
MaxRecordCount: 1000
Supported Query Formats: JSON, geoJSON
Min Scale: 0
Max Scale: 0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: false
Can Modify Layer: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports Datum Transformation: true
Extent:
XMin: -77.760850307
YMin: 0.974119872000017
XMax: -73.036837793
YMax: 5.779520042000001
Spatial Reference: 4686
(4686)
Drawing Info:
Renderer:
Simple Renderer:
Symbol:
Label:
Description:
Transparency: 0
Labeling Info:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: false
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
Supports Binning LOD: false
Supports Query With LOD Spatial Reference: false
HasZ: false
HasM: false
Has Attachments: false
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Type ID Field: null
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID
)
-
ID_SEV
(
type: esriFieldTypeString, alias: Identificador Sondeo Eléctrico Vertical, length: 50
)
-
COORDENADA_X
(
type: esriFieldTypeDouble, alias: Coordenada Este
)
-
COORDENADA_Y
(
type: esriFieldTypeDouble, alias: Coordenada Norte
)
-
SISTEMA_COORDENADAS
(
type: esriFieldTypeSmallInteger, alias: Sistema de coordenadas
, Coded Values:
[1: MAGNA_Colombia_Este_Este]
, [3: MAGNA_Colombia_Bogota]
, [5: MAGNA_Colombia_Oeste_Oeste]
, ...4 more...
)
-
LATITUD
(
type: esriFieldTypeDouble, alias: Latitud
)
-
LONGITUD
(
type: esriFieldTypeDouble, alias: Longitud
)
-
ALTURA_SOBRE_NIVEL_MAR
(
type: esriFieldTypeDouble, alias: Altura sobre el nivel del mar
)
-
ALTURA_ELIPSOIDAL
(
type: esriFieldTypeDouble, alias: Altura elipsoidal
)
-
LOCALIDAD
(
type: esriFieldTypeString, alias: Localidad, length: 50
)
-
FECHA
(
type: esriFieldTypeDate, alias: Fecha, length: 8
)
-
RUMBO
(
type: esriFieldTypeString, alias: Rumbo, length: 10
)
-
MN_2
(
type: esriFieldTypeString, alias: MN/2, length: 50
)
-
AB_2
(
type: esriFieldTypeDouble, alias: AB/2
)
-
OBSER_CAMPO
(
type: esriFieldTypeString, alias: Observaciones campo, length: 250
)
-
RESISTCAMPO_1_5M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 1,5 m
)
-
RESISTCAMPO_2_5M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 2,5 m
)
-
RESISTCAMP_4M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 4 m
)
-
RESISTCAMPO_6M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 6 m
)
-
RESISTCAMPO_8M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 8 m
)
-
RESISTCAMPO_10M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 10 m
)
-
RESISTCAMPO_12M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 12 m
)
-
RESISTCAMPO_15M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 15 m
)
-
RESISTCAMPO_20M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 20 m
)
-
RESISTCAMPO_12M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 12 m – Acople
)
-
RESISTCAMPO_15M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 15 m – Acople
)
-
RESISTCAMPO_20M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 20 m – Acople
)
-
RESISTCAMPO_25M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 25 m
)
-
RESISTCAMPO_30M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 30 m
)
-
RESISTCAMPO_40M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 40 m
)
-
RESISTCAMPO_30M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 30 m – Acople
)
-
RESISTCAMPO_40M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 40 m – Acople
)
-
RESISTCAMPO_50M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 50 m
)
-
RESISTCAMPO_60M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 60 m
)
-
RESISTCAMPO_75M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 75 m
)
-
RESISTCAMPO_100M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 100 m
)
-
RESISTCAMPO_60M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 60 m – Acople
)
-
RESISTCAMPO_75M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 75 m – Acople
)
-
RESISTCAMPO_100M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 100 m – Acople
)
-
RESISTCAMPO_125M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 125 m
)
-
RESISTCAMPO_150M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 150 m
)
-
RESISTCAMPO_175M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 175 m
)
-
RESISTCAMPO_200M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 200 m
)
-
RESISTCAMPO_150M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 150 m – Acople
)
-
RESISTCAMPO_175M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 175 m – Acople
)
-
RESISTCAMPO_200M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 200 m– Acople
)
-
RESISTCAMPO_250M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 250 m
)
-
RESISTCAMPO_300M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 300 m
)
-
RESISTCAMPO_350M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 350 m
)
-
RESISTCAMPO_400M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 400 m
)
-
RESISTCAMPO_300M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 300 m – Acople
)
-
RESISTCAMPO_350M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 350 m – Acople
)
-
RESISTCAMPO_400M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 400 m – Acople
)
-
RESISTCAMPO_500M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 500 m
)
-
RESISTCAMPO_600M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 600 m
)
-
RESISTCAMPO_700M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 700 m
)
-
RESISTCAMPO_600M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 600 m – Acople
)
-
RESISTCAMPO_700M_ACOPLE
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 700 m – Acople
)
-
RESISTCAMPO_800M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 800 m
)
-
RESISTCAMPO_900M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 900 m
)
-
RESISTCAMPO_1000M
(
type: esriFieldTypeDouble, alias: Resistividad medida en campo a 1000 m
)
-
NUMEROPLANCHA
(
type: esriFieldTypeString, alias: Numero de plancha, length: 50
)
-
EQUIPOUSADO
(
type: esriFieldTypeString, alias: Equipo usado, length: 50
)
-
TIPOARREGLO
(
type: esriFieldTypeSmallInteger, alias: Tipo de Arreglo
, Coded Values:
[1: Wenner]
, [2: Schlumberger]
, [3: Dipolo-Dipolo]
, ...8 more...
)
-
NOMBREOPERADOR
(
type: esriFieldTypeString, alias: Nombre del Operador, length: 100
)
-
GRUPOTRABAJO
(
type: esriFieldTypeString, alias: Grupo de Trabajo, length: 50
)
-
INSTITUCION
(
type: esriFieldTypeString, alias: Institución, length: 50
)
-
CORRELACIONLITOLOGICA_PROC
(
type: esriFieldTypeString, alias: Correlación Litológica, length: 150
)
-
ERRORAJUSTECURVA_PROC
(
type: esriFieldTypeString, alias: Error de ajuste de las curvas, length: 10
)
-
PROF_INVEST
(
type: esriFieldTypeDouble, alias: Profundidad de investigación Estimada
)
-
RESPROCES_1
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 1
)
-
PROFPROCES_1
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 1
)
-
RESPROCES_2
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 2
)
-
PROFPROCES_2
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 2
)
-
RESPROCES_3
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 3
)
-
PROFPROCES_3
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 3
)
-
RESPROCES_4
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 4
)
-
PROFPROCES_4
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 4
)
-
RESPROCES_5
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 5
)
-
PROFPROCES_5
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 5
)
-
RESPROCES_6
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 6
)
-
PROFPROCES_6
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 6
)
-
RESPROCES_7
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 7
)
-
PROFPROCES_7
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 7
)
-
RESPROCES_8
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 8
)
-
PROFPROCES_8
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 8
)
-
RESPROCES_9
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 9
)
-
PROFPROCES_9
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 9
)
-
RESPROCES_10
(
type: esriFieldTypeDouble, alias: Resistividad Procesada 10
)
-
PROFPROCES_10
(
type: esriFieldTypeDouble, alias: Profundidad Procesada 10
)
-
CITA_BIBLIOGRAFICA
(
type: esriFieldTypeString, alias: Cita Bibliográfica, length: 200
)
-
REFERENCIA_BIBLIOGRAFICA
(
type: esriFieldTypeString, alias: Referencia Bibliográfica, length: 600
)
-
SHAPE
(
type: esriFieldTypeGeometry, alias: Shape
)
Supported Operations:
Query
Query Attachments
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata